Contact
For further information about this product, please contact us.
News
24 July 2007 Smiths Detection awarded initial contract to supply M4 JCAD, the U.S. Military’s new generation chemical agent detector [more]
8 June 2007 Smiths Detection introduces multi-sensor handheld chemical identifier for emergency responders [more]
22 May 2007 Smiths Detection launches new hand-held biological agent detector - Bio-Seeq Plus [more]
22 May 2007 Smiths Detection to help protect Swedish defence forces against chemical warfare agents [more]
15 May 2007 Smiths Detection chosen to commercialise early warning system for chemical terrorist attacks [more]
Options
DuraDisks
Diamond ATR elements with multi-reflection capability for enhanced sensitivity
1 Reflection Option
- Suitable for liquids requiring high throughput energy as well as solid samples that demand good contact pressure
- Good signal to noise in the diamond lattice region between 2200 and 1900 cm–1
- Ideal for very rigid samples
3 Reflection Option
- High signal to noise in the spectral fingerprint region
- Ideal for solid and liquid samples requiring more pathlength sensitivity than the single reflection
9 Reflection Option
- Used for liquid, pastes and gel samples that require maximum sensitivity
- Highest signal to noise attainable with diamond ATR. Ideal for complex mixtures and low infrared absorbers in the spectral fingerprint region
- The diamond is recessed for liquid retention
Heating & Cooling Autotune Controller
Heats temperatures up to 100°C
- Permits calibrated, elevated temperature studies, at temperatures up to 100°C
- Provides accuracy of +/- 0.1°C across the full temperature range
The package consists of an Autotune Controller with an easy to read, dual four-digit display that shows both the actual temperature of the DuraDisk as well as the target temperature. The DuraDisk temperature is monitored with an integral RTD.
AmplifiIR
Unique variable 45° specular reflection device for thin film analyses
The AmplifIR utilizes transflectance principles, measuring through the surface coating
Versatility to increase the number of reflections to increase the effective pathlength measurement’s sensitivity The effective pathlength extends use into the sub-500Å range
The IRbeam is externally reflected between the sample surface and an adjustable gold coated mirror. Raising or lowering the mirror increases or decreases the number of reflections.
Gas and Liquid Flow Cell
Gas Cell
High-pressure gas cell for FT-IR analysis
Capable of testing gases up to 1000 psi Compact in size yet creates a generous 10cm path length Permits analysis of harsh and corrosive gases with permanently aligned infrared multi-pass mirrors isolated from the gas by sapphire-coated zinc selenide windows sealed with Kalrez® O-rings#
Liquid & Flow Cell
- For air sensitive samples, performing reaction analyses or other dynamic studies
- Permit convenient flow-through studies of aqueous and non-aqueous liquids at ambient or elevated temperatures
- Complete chemical inertness and easy cleaning chemical samples only contact stainless steel and Teflon® surfaces
- Standard thread for both Luer Lok® and Swagelok® fittings
- Rrated to 100 psi
- Available on 1, 3 and 9 reflection DuraDisks
- Can works with heated DuraDisks
ATR Libraries
For further information click
here.
For further information about this product, please
contact us.